Huawei's 448Gbps AI Switch Interconnect: PAM6 vs PAM4 Trade-offs
Huawei presents OIF 448G AI Workshop research on next-gen 448Gbps single-lane interconnects for AI clusters, comparing PAM4 and PAM6 modulation across intra-rack, inter-rack, and inter-DC architectures while analyzing FEC schemes, connector limits, and reliability trade-offs for electrical and optical links.
Research Background
At the OIF 448G AI Workshop, Huawei presented a system-level study of 448Gbps single-lane interconnects for AI clusters. The work stems from TEF meeting consensus that AI Scale-Out (horizontal) and Scale-Up (tightly coupled) expansion urgently requires next-generation interconnects, with electrical signaling identified as the greatest unknown and core challenge. The industry has been evaluating BIDI, SE-MIMO, and PAM4/6/8 modulation schemes.
Current industry status shows the electrical interface remains the bottleneck: high-speed optical hardware exists, but engineering data for 448G/lane electrical links is insufficient. The report therefore focuses on comparing PAM4 and PAM6 from a whole-switch-system perspective.
Three-Layer Switch System Architecture Analysis
1. Intra-Rack Interconnect
Intra-rack connections rely primarily on electrical interconnects: orthogonal backplanes, CPC connectors, 2D connectors, DAC copper cables, AEC active electrical cables, and Retimer/Redriver signal retiming devices.
CEI standards have defined insertion-loss and reach targets for 50G, 100G, and 200Gbps backplane, VSR (short reach), and LR (long reach) channels. At 200G, passive copper cables reach 2 meters maximum, while AEC can extend to adjacent racks.
448Gbps faces severe challenges: 1D connector bandwidth and insertion loss become bottlenecks; ball-to-ball bare-die loss metrics are still unclear. Intra-rack Scale-Up scenarios still prefer to continue using electrical interconnects.
2. Inter-Rack Interconnect
Real-world demand: Switch port radix is evolving from 51 to 102 to support flattened network topologies, while meeting hard reliability requirements for AI training and inference.
Optional hardware forms: Pluggable optical modules, NPO (near-package optics), and CPO (co-packaged optics).
Reliability and maintainability comparison:
MTBF: A pluggable module failure affects only 8 lanes; a switch chassis failure affects all 512 lanes. NPO with a socket introduces maintenance difficulty; CPO optical engines are soldered to the ASIC, requiring return-to-factory repair.
Hot-plug: Traditional pluggables support hot-plug; socketed NPO replacement is difficult; soldered CPO cannot be replaced in the field.
3. Inter-DC Interconnect
OIF is advancing 1600ZR/ZR+ and 1.6T-CL standards for AI-campus short-reach coherent applications, pursuing point-to-point, low-power coherent solutions.
Modulation, SNR, and FEC Analysis
Candidate modulations: PAM4 and PAM6, using KP4 as the baseline FEC.
PAM4: 212.5 GBd symbol rate; requires 18.2 dB SNR at 1e-4 BER.
PAM6: 170 GBd symbol rate; lower symbol rate reduces channel bandwidth demand, but requires 21.8 dB SNR at 1e-4 BER.
Electrical interconnect (backplane) simulation shows that with KP4-FEC combined with equalization algorithms (MLSE/MMSE-DFE), both PAM4 and PAM6 have the potential to support >40 dB insertion loss.
FEC architecture combinations:
Inner-FEC (inner layer): Extends electrical link budget; suitable for AEC active cables and retimed pluggables.
OFEC/FEC2 (outer layer): Extends optical reach; mandatory for ZR/ZR+ coherent optics.
Coherent optics scenario: PAM6 helps reduce AUI-C2M electrical interface pressure; with appropriate Inner-FEC, the optical-side performance gap among PAM4, PAM6, and 16QAM is limited.
Solving 448Gbps Interconnect Multi-Path Technical Issues
To overcome high-speed connector and channel bandwidth bottlenecks, Huawei outlines several complementary technology directions:
Connectors: CPC connectors achieve >100 GHz bandwidth; EEI project HDC targets front-panel pluggables, developing next-generation 2D connectors and Twinax cables.
Substrate and packaging: Glass substrates, ultra-high-density PCBs, polymer fill materials; TSMC-COUPE and similar 2.5D/3D optical engine chiplet packaging.
Algorithms and coding: Dual-binary PAM4, non-linear compensation, low-complexity MAP decoding.
Architectural trade-offs:
Intra-rack: adopt PAM6 electrical interconnect to extend reach.
IMDD optical side: use PAM4 to lower power.
Alternative: "lower port speed, increase port count" to achieve >1 meter backplane/cable transmission.
Key Conclusions
Electrical interconnects targeting 1-meter cable specs require new connector and packaging technologies as enablers.
NPO and CPO can reduce IMDD optical link power, but MTBF and field maintainability must be included in whole-system evaluation.
For transmission distances beyond 2 km, the importance of coherent optics further increases.
Maintaining Ethernet plug-and-play capability is a critical prerequisite; pluggable form factors must be retained.
The core of AI-era switch system design: find a new system balance point between electrical and optical interconnects , requiring comprehensive trade-offs among power, loss, SNR, FEC, reliability, and maintainability.
Signed-in readers can open the original source through BestHub's protected redirect.
This article has been distilled and summarized from source material, then republished for learning and reference. If you believe it infringes your rights, please contactand we will review it promptly.
Architects' Tech Alliance
Sharing project experiences, insights into cutting-edge architectures, focusing on cloud computing, microservices, big data, hyper-convergence, storage, data protection, artificial intelligence, industry practices and solutions.